Aplikasi: | Pengolahan Limbah, Pengolahan Air Limbah, Pengolahan Air Limbah, limbah domestik atau air limbah ind | Kapasitas: | 10-5000 M3 / d |
---|---|---|---|
Nama Produk: | Biorector Membran MBR | Bahan: | Baja Karbon / Baja tahan karat, Baja Tahan Karat, PVDF, Serat diperkuat PVDF, Baja Karbon anti karat |
Tipe: | Bagian Filter Air, instalasi pengolahan limbah, konstruksi Intergrative atau Civil, Membran Lembar D | Warna: | Customerized |
Pemakaian: | Pengolahan limbah, Pemurnian, Peralatan Pengolahan Air Limbah Industri | Fungsi: | Instalasi Penjernihan Air, rumah sakit, instalasi pengolahan air limbah, peternakan hewan, dll |
Jaminan: | 1 tahun | Bahan Membran: | PVDF (PET linning) |
Ukuran: | Ukuran disesuaikan | ||
Cahaya Tinggi: | reaktor biologis membran,serat berongga mbr |
Sistem Pengolahan Air Anti Pencemaran Industri Mbr Kapasitas 10 - 5000 M3 / D
Ukuran H * L * W (mm): 2000 * 1250 * 30
Area membran: 34,5m²
Ukuran sutra: 2.5mm
Ukuran pori: 0.2mm
Fluks: 10-30 LM / H
Kolom pendukung: SUS
Bahan serat berongga: PVDF
Suhu kerja: 10-40 ℃
Kisaran PH: 2-12
Kondisi dan Metode penggunaan
1. Membran hidrofilisitas dan pelembab
The reinforced composite PVDF membrane adopts hydrophilic modified PVDF raw material, and the membrane has good hydrophilicity, and no hydrophilic treatment is needed at the site. Membran komposit PVDF yang diperkuat mengadopsi bahan baku PVDF yang dimodifikasi hidrofilik, dan membran tersebut memiliki hidrofilisitas yang baik, dan tidak diperlukan perawatan hidrofilik di lokasi. However, if the diaphragm is not put into use immediately after installation, or if it needs to be parked for a while during use, please ensure that the diaphragm is submerged in water or always wet. Namun, jika diafragma tidak segera digunakan setelah pemasangan, atau jika perlu diparkir sebentar selama penggunaan, harap pastikan bahwa diafragma terendam air atau selalu basah.
2. Perawatan fluks membran dan pembersihan membran
The aeration system of the diaphragm is constructed by using a perforated aeration method, and the bubbles and water flow generated by the aeration are fully shaken to achieve self-cleaning of the membrane. Sistem aerasi diafragma dibangun dengan menggunakan metode aerasi berlubang, dan gelembung dan aliran air yang dihasilkan oleh aerasi sepenuhnya terguncang untuk mencapai pembersihan sendiri membran. The intermittent operation mode is adopted, and the self-priming pump suctions for 10 to 12 minutes and stops for 2 to 3 minutes, which can effectively prevent the membrane pores from being clogged and ensure long-term and stable operation of membrane separation. Mode operasi intermiten diadopsi, dan pompa self-priming menyedot selama 10 hingga 12 menit dan berhenti selama 2 hingga 3 menit, yang secara efektif dapat mencegah pori-pori membran tersumbat dan memastikan operasi pemisahan membran yang stabil dan berjangka panjang. When used for the first time, the biochemical pool microbial culture achieved good activity, and when the viscosity was small, the membrane began to be put into operation. Ketika digunakan untuk pertama kalinya, biakan mikroba biokimia mencapai aktivitas yang baik, dan ketika viskositasnya kecil, membran mulai dioperasikan.
When the system is running, the constant flow method is adopted, and the suction negative pressure can be read by the electric contact type pressure gauge, and the initial diaphragm operation negative pressure is -0.01 to -0.03Mpa. Ketika sistem berjalan, metode aliran konstan diadopsi, dan tekanan negatif hisap dapat dibaca oleh pengukur tekanan tipe kontak listrik, dan tekanan negatif operasi diafragma awal adalah -0,01 hingga -0,03Mpa. When the conditions permit, the water can be siphoned, but the difference between the liquid level of the biochemical pool and the outlet pool should be 3.0-4.0 meters, the membrane is less likely to be polluted, the water is more stable, and the service period is longer. Ketika kondisi memungkinkan, air dapat tersedot, tetapi perbedaan antara tingkat cairan kolam biokimia dan kolam outlet harus 3,0-4,0 meter, membran cenderung tercemar, air lebih stabil, dan masa layanan lebih lama. When the operating negative pressure exceeds -0.06 MPa, the diaphragm needs to be chemically cleaned in time. Ketika tekanan negatif operasi melebihi -0,06 MPa, diafragma perlu dibersihkan secara kimia dalam waktu. The cleaning method is to place the membrane stack in the chemical cleaning tank or the membrane module piece is removed from the membrane frame, rinse the surface of the membrane with clean water, remove the activated sludge attached to the surface of the membrane, and soak for several hours with a 0.5% NaClO solution. Metode pembersihan adalah dengan menempatkan tumpukan membran di tangki pembersih bahan kimia atau potongan modul membran dikeluarkan dari bingkai membran, bilas permukaan membran dengan air bersih, singkirkan lumpur aktif yang menempel pada permukaan membran, dan rendam. selama beberapa jam dengan larutan NaClO 0,5%. The bacteria adhering to the surface of the membrane are killed, the organic matter and the colloidal substance attached to the surface of the membrane are removed, and the membrane is washed with water, and the membrane flux can be recovered. Bakteri yang menempel pada permukaan membran terbunuh, bahan organik dan zat koloid yang melekat pada permukaan membran dihilangkan, dan membran dicuci dengan air, dan fluks membran dapat dipulihkan. If the salt in the water is more likely to scale on the surface of the membrane, it can be soaked with 2 to 3% hydrochloric acid for about 1 hour. Jika garam dalam air lebih mungkin untuk menskalakan permukaan membran, ia dapat direndam dengan 2 hingga 3% asam klorida selama sekitar 1 jam. Care should be taken in cleaning to prevent damage to the membrane. Perawatan harus diambil dalam pembersihan untuk mencegah kerusakan pada membran.
3. Transportasi dan penanganan
The entire transportation process should ensure that the ambient temperature of the device is within the range of 5-40 °C to avoid damage to the diaphragm. Seluruh proses transportasi harus memastikan bahwa suhu sekitar perangkat berada dalam kisaran 5-40 ° C untuk menghindari kerusakan pada diafragma. And avoid exposing the device to sunlight, so as not to damage the engineering plastics on the device. Dan hindari memaparkan perangkat ke sinar matahari, agar tidak merusak plastik rekayasa pada perangkat.
Satu karton akan berisi 10-30 pcs sesuai dengan ukuran membran.